3 back-panel leds, 1 i/o controller module leds, Back-panel leds – Dot Hill Systems II 200 FC User Manual

Page 103: I/o controller module leds

background image

Chapter 6 Checking LEDs

6-5

A similar situation occurs when you add an expansion unit or JBOD and there is a
mismatch between the SES or PLD firmware of the RAID array and that of the
expansion unit, or between two expansion units.

See “Upgrading SES and PLD Firmware” on page 7-8 for information about
upgrading SES and PLD firmware.

6.3

Back-Panel LEDs

The back-panel LED colors indicate the conditions described in the following figures
and tables.

Note –

To test that the LEDs work, using a paper clip, press and hold the Reset button

for 5 seconds. All the LEDs should change from green to amber when you perform this
test. Any LED that fails to light indicates a problem with the LED. When you release
the Reset button, the LEDs return to their initial state.

6.3.1

I/O Controller Module LEDs

Figure 6-3 shows the SANnet II 200 FC array I/O controller module and the LEDs on
its back panel.

Figure 6-3 SANnet II 200 FC Array I/O Controller Module and Battery Module

LEDs

Figure 6-4 shows the SANnet II 200 SATA array I/O controller module and the LEDs
on its back panel.

Ethernet active

Ethernet link

Battery

SFP link status

SFP speed

RAID controller status

I/O activity

Cache