3 back-panel leds, 1 i/o controller module leds, Back-panel leds – Dot Hill Systems II 200 FC User Manual
Page 103: I/o controller module leds
Chapter 6 Checking LEDs
6-5
A similar situation occurs when you add an expansion unit or JBOD and there is a
mismatch between the SES or PLD firmware of the RAID array and that of the
expansion unit, or between two expansion units.
See “Upgrading SES and PLD Firmware” on page 7-8 for information about
upgrading SES and PLD firmware.
6.3
Back-Panel LEDs
The back-panel LED colors indicate the conditions described in the following figures
and tables.
Note –
To test that the LEDs work, using a paper clip, press and hold the Reset button
for 5 seconds. All the LEDs should change from green to amber when you perform this
test. Any LED that fails to light indicates a problem with the LED. When you release
the Reset button, the LEDs return to their initial state.
6.3.1
I/O Controller Module LEDs
Figure 6-3 shows the SANnet II 200 FC array I/O controller module and the LEDs on
its back panel.
Figure 6-3 SANnet II 200 FC Array I/O Controller Module and Battery Module
LEDs
Figure 6-4 shows the SANnet II 200 SATA array I/O controller module and the LEDs
on its back panel.
Ethernet active
Ethernet link
Battery
SFP link status
SFP speed
RAID controller status
I/O activity
Cache