8-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005
Note –
It is important to know the cause of the error condition because how you
silence the alarm depends on the cause of the alarm.
To silence the alarm, perform the following steps:
1. Check the error messages, event logs, and LED activity to determine the cause of the
alarm.
Component event messages include but are not limited to the following:
■
SES/PLD firmware mismatch
■
Temperature
■
Cooling element
■
Power supply
■
Battery
■
Fan
■
Voltage sensor
Caution –
Be particularly careful to observe and rectify a temperature failure alarm. If
you detect this alarm, shut down the controller. Shut down the server as well if it is
actively performing I/O operations to the affected array. Otherwise, system damage
and data loss can occur.
See Appendix C for more information about component alarms.