IP Core Signals

III-66

Slave Controller

– IP Core for Xilinx FPGAs

8.5.2

RMII Interface

Table 24 lists the signals used with RMII.

Table 24: PHY Interface RMII

Condition

Name

Direction

Description

Selected

communication

interface Port0/Port1 =

RMII

CLK50

INPUT

50 MHz reference clock
signal from PLL (rising edge
synchronous with rising
edge of CLK100), also
connected to PHY

nRMII_LINK0

INPUT

0: 100 Mbit/s (Full

Duplex) link at port 0

1: no link at port 0

RMII_RX_DV0

INPUT

Carrier sense/receive data
valid port 0

RMII_RX_DATA0[1:0]

INPUT

Receive data port 0

RMII_RX_ERR0

INPUT

Receive error port 0

RMII_TX_ENA0

OUTPUT

Transmit enable port 0

RMII_TX_DATA0[1:0]

OUTPUT

Transmit data port 0

2 communication ports

and

selected

communication

interface Port1 = RMII

nRMII_LINK1

INPUT

0: 100 Mbit/s (Full

Duplex) link at port 1

1: no link at port 1

RMII_RX_DV1

INPUT

Carrier sense/receive data
valid port 1

RMII_RX_DATA1[1:0]

INPUT

Receive data port 1

RMII_RX_ERR1

INPUT

Receive error port 1

RMII_TX_ENA1

OUTPUT

Transmit enable port 1

RMII_TX_DATA1[1:0]

OUTPUT