Basler Electric BE1-11 Modbus Protocol User Manual
Page 47

9424200774 Rev B
41
BE1-11
Register Table
Name
Description
Register
Type Bytes Writable
Unit
Range
Style
CT Circuit 2
I2 Angle
10302
Float
4
R
Degree
0 - 360
FGIMT
CT Circuit 2
3I0 Angle
10304
Float
4
R
Degree
0 - 360
FGIMT
CT Circuit 2
IG
10306
Float
4
R
Amp
0 - 2000000000
FGIMT
CT Circuit 2
IG Angle
10308
Float
4
R
Degree
0 - 360
FGIMT
Frequency Meter
Phase Frequency
10310
Float
4
R
Hertz
10 - 150
FGIMT
Reserved
10312-41
Frequency Meter
Auxiliary Frequency
10318
Float
4
R
Hertz
10 - 150
FGIMT
Reserved
10320-41
Analog Input Meter 1
Scaled
10342
Float
4
R
n/a
n/a
FGIMT
Analog Input Meter 2
Scaled
10344
Float
4
R
n/a
n/a
FGIMT
Analog Input Meter 3
Scaled
10346
Float
4
R
n/a
n/a
FGIMT
Analog Input Meter 4
Scaled
10348
Float
4
R
n/a
n/a
FGIMT
Analog Input Meter 5
Scaled
10350
Float
4
R
n/a
n/a
FGIMT
Analog Input Meter 6
Scaled
10352
Float
4
R
n/a
n/a
FGIMT
Analog Input Meter 7
Scaled
10354
Float
4
R
n/a
n/a
FGIMT
Analog Input Meter 8
Scaled
10356
Float
4
R
n/a
n/a
FGIMT
Analog Output Meter 1
Scaled
10358
Float
4
R
n/a
n/a
FGIMT
Analog Output Meter 2
Scaled
10360
Float
4
R
n/a
n/a
FGIMT
Analog Output Meter 3
Scaled
10362
Float
4
R
n/a
n/a
FGIMT
Analog Output Meter 4
Scaled
10364
Float
4
R
n/a
n/a
FGIMT
Analog Output Meter 5
Scaled
10366
Float
4
R
n/a
n/a
FGIMT
Analog Output Meter 6
Scaled
10368
Float
4
R
n/a
n/a
FGIMT
Analog Output Meter 7
Scaled
10370
Float
4
R
n/a
n/a
FGIMT
Analog Output Meter 8
Scaled
10372
Float
4
R
n/a
n/a
FGIMT
RTD Meter 1-1
Scaled
10374
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 1-2
Scaled
10376
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 1-3
Scaled
10378
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 1-4
Scaled
10380
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 1-5
Scaled
10382
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 1-6
Scaled
10384
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 1-7
Scaled
10386
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 1-8
Scaled
10388
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 1-9
Scaled
10390
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 1-10
Scaled
10392
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 1-11
Scaled
10394
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 1-12
Scaled
10396
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-1
Scaled
10398
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-2
Scaled
10400
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-3
Scaled
10402
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-4
Scaled
10404
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-5
Scaled
10406
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-6
Scaled
10408
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-7
Scaled
10410
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-8
Scaled
10412
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-9
Scaled
10414
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-10
Scaled
10416
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-11
Scaled
10418
Float
4
R
n/a
0 - 250
FGIMT
RTD Meter 2-12
Scaled
10420
Float
4
R
n/a
0 - 250
FGIMT
Phase Differential Meter
Iop A
10422
Float
4
R
X Tap
0 - 100000
GMT
Phase Differential Meter
Ir A
10424
Float
4
R
X Tap
0 - 100000
GMT
Phase Differential Meter
Iop B
10426
Float
4
R
X Tap
0 - 100000
GMT
Phase Differential Meter
Ir B
10428
Float
4
R
X Tap
0 - 100000
GMT
Phase Differential Meter
Iop C
10430
Float
4
R
X Tap
0 - 100000
GMT
Phase Differential Meter
Ir C
10432
Float
4
R
X Tap
0 - 100000
GMT
Learned Motor Data
Average Maximum Thermal
10434
Float
4
R
Percent
0 - 1000
M
Learned Motor Data
Average Max Current
10436
Float
4
R
Amp
0 - 2000000000
M
Learned Motor Data
Average Min Voltage
10438
Float
4
R
Volt
0 - 2000000000
M
Learned Motor Data
Average Max RTD Group 1
10440
Float
4
R
n/a
0 - 250
M
Learned Motor Data
Average Max RTD Group 2
10442
Float
4
R
n/a
0 - 250
M
Learned Motor Data
Average Max RTD Group 3
10444
Float
4
R
n/a
0 - 250
M
Learned Motor Data
Average Max RTD Group 4
10446
Float
4
R
n/a
0 - 250
M
Learned Motor Data
Average Start Duration Min
10448
Int32
4
R
n/a
0 - 500000
M
Learned Motor Data
Average Start Duration Sec
10450
Int32
4
R
n/a
0 - 500000
M
Motor Meter
Thermal Capacity
10452
Float
4
R
Percent
0 - 2001
M
Motor Meter
Current Unbalance
10454
Float
4
R
n/a
n/a
M
Motor Meter
Voltage Unbalance
10456
Float
4
R
n/a
n/a
M
Motor Meter
Effective Motor Load
10458
Float
4
R
n/a
n/a
M
Phase Differential Meter
Iop 2
nd
A
10460
Float
4
R
Amp
0 - 100000
GT
Phase Differential Meter
Iop 2
nd
B
10462
Float
4
R
Amp
0 - 100000
GT
Phase Differential Meter
Iop 2
nd
C
10464
Float
4
R
Amp
0 - 100000
GT
Phase Differential Meter
Iop 5
th
A
10466
Float
4
R
Amp
0 - 100000
GT
Phase Differential Meter
Iop 5
th
B
10468
Float
4
R
Amp
0 - 100000
GT
Phase Differential Meter
Iop 5
th
C
10470
Float
4
R
Amp
0 - 100000
GT
Differential Meter 87N-2
Iop
10472
Float
4
R
Amp
0 - 100000
T
Differential Meter 87N-2
Ir
10474
Float
4
R
Amp
0 - 100000
T
Learned Motor Data
Average Maximum
RTD Group 5
10476
Float
4
R
n/a
0 - 250
M