Direct operate, Binary points – Basler Electric BE1-11 Modbus Protocol User Manual
Page 21

9424200774 Rev B
15
BE1-11
Register Table
Name
Description
Register
Type
Bytes
Writable
Range
Settings Group
Operate
718
Int32
4
R W
Settings Group 0=0
Settings Group 1=1
Settings Group 2=2
Settings Group 3=3
Local Contacts
Contact Output 6 Override State Operate
720
Uint8
1
R W
Off=0
On=1
Local Contacts
Contact Output 7 Override State Operate
721
Uint8
1
R W
Off=0
On=1
Local Contacts
Contact Output 8 Override State Operate
722
Uint8
1
R W
Off=0
On=1
Direct Operate
Name
Description
Register
Type
Bytes
Writable
Range
101
Untag
800
Uint32
4
R W
Disable Tag=0
Info Tag=1
Blocking Tag=2
101
Tag
802
Uint32
4
R W
Disable Tag=0
Info Tag=1
Blocking Tag=2
Demand Meter Circuit 1
Reset Demands
804
Uint32
4
R W
Operate=1
Current Demand Circuit 2
Reset Demands
806
Uint32
4
R W
Operate=1
G Current Demand Circuit 2
Reset Demands
808
Uint32
4
R W
Operate=1
Binary Points
Name
Description
Register
Type
Bytes Writable
Range
Style
60FL
60FL Alarm
900 bit 0
Uint16 2
R
True=1 False=0
FGIMT
24
Block
900 bit 1
Uint16 2
R
True=1 False=0
GIT
24
Pickup
900 bit 2
Uint16 2
R
True=1 False=0
GIT
24
Trip
900 bit 3
Uint16 2
R
True=1 False=0
GIT
24
Target
900 bit 4
Uint16 2
R
True=1 False=0
GIT
24
Alarm
900 bit 5
Uint16 2
R
True=1 False=0
GIT
25
Block
900 bit 6
Uint16 2
R
True=1 False=0
FGI
25
Status
900 bit 7
Uint16 2
R
True=1 False=0
FGI
25
VM1 Status
900 bit 8
Uint16 2
R
True=1 False=0
FGI
27P-1
Block
900 bit 9
Uint16 2
R
True=1 False=0
FGIMT
27P-1
Pickup
900 bit 10
Uint16 2
R
True=1 False=0
FGIMT
27P-1
Trip
900 bit 11
Uint16 2
R
True=1 False=0
FGIMT
27P-1
Target A
900 bit 12
Uint16 2
R
True=1 False=0
FGIMT
27P-1
Target B
900 bit 13
Uint16 2
R
True=1 False=0
FGIMT
27P-1
Target C
900 bit 14
Uint16 2
R
True=1 False=0
FGIMT
27P-2
Block
900 bit 15
Uint16 2
R
True=1 False=0
FGIMT
27P-2
Pickup
901 bit 0
Uint16 2
R
True=1 False=0
FGIMT
27P-2
Trip
901 bit 1
Uint16 2
R
True=1 False=0
FGIMT
27P-2
Target A
901 bit 2
Uint16 2
R
True=1 False=0
FGIMT
27P-2
Target B
901 bit 3
Uint16 2
R
True=1 False=0
FGIMT
27P-2
Target C
901 bit 4
Uint16 2
R
True=1 False=0
FGIMT
27P-3
Block
901 bit 5
Uint16 2
R
True=1 False=0
FGIMT
27P-3
Pickup
901 bit 6
Uint16 2
R
True=1 False=0
FGIMT
27P-3
Trip
901 bit 7
Uint16 2
R
True=1 False=0
FGIMT
27P-3
Target A
901 bit 8
Uint16 2
R
True=1 False=0
FGIMT
27P-3
Target B
901 bit 9
Uint16 2
R
True=1 False=0
FGIMT
27P-3
Target C
901 bit 10
Uint16 2
R
True=1 False=0
FGIMT
27P-4
Block
901 bit 11
Uint16 2
R
True=1 False=0
FGIMT
27P-4
Pickup
901 bit 12
Uint16 2
R
True=1 False=0
FGIMT
27P-4
Trip
901 bit 13
Uint16 2
R
True=1 False=0
FGIMT
27P-4
Target A
901 bit 14
Uint16 2
R
True=1 False=0
FGIMT
27P-4
Target B
901 bit 15
Uint16 2
R
True=1 False=0
FGIMT
27P-4
Target C
902 bit 0
Uint16 2
R
True=1 False=0
FGIMT
27P-5
Block
902 bit 1
Uint16 2
R
True=1 False=0
FGIT
27P-5
Pickup
902 bit 2
Uint16 2
R
True=1 False=0
FGIT
27P-5
Trip
902 bit 3
Uint16 2
R
True=1 False=0
FGIT
27P-5
Target A
902 bit 4
Uint16 2
R
True=1 False=0
FGIT
27P-5
Target B
902 bit 5
Uint16 2
R
True=1 False=0
FGIT
27P-5
Target C
902 bit 6
Uint16 2
R
True=1 False=0
FGIT
27X-1
Block
902 bit 7
Uint16 2
R
True=1 False=0
FGIT
27X-1
Pickup
902 bit 8
Uint16 2
R
True=1 False=0
FGIT
27X-1
Trip
902 bit 9
Uint16 2
R
True=1 False=0
FGIT
27X-1
Target 3V0
902 bit 10
Uint16 2
R
True=1 False=0
FGIT
27X-1
Target V2
902 bit 11
Uint16 2
R
True=1 False=0
FGIT
27X-1
Target AUX
902 bit 12
Uint16 2
R
True=1 False=0
FGIT
27X-1
Target 3RD
902 bit 13
Uint16 2
R
True=1 False=0
FGIT
27X-1
Target V1
902 bit 14
Uint16 2
R
True=1 False=0
FGIT
27X-2
Block
902 bit 15
Uint16 2
R
True=1 False=0
FGIT
27X-2
Pickup
903 bit 0
Uint16 2
R
True=1 False=0
FGIT
27X-2
Trip
903 bit 1
Uint16 2
R
True=1 False=0
FGIT