Basler Electric BE1-11 Modbus Protocol User Manual
Page 29

9424200774 Rev B
23
BE1-11
Register Table
Name
Description
Register
Type
Bytes Writable
Range
Style
Alarms
Programmable Alarm 8
937 bit 4
Uint16 2
R
True=1 False=0
FGIMT
Major Alarm
Alarm Output
937 bit 5
Uint16 2
R
True=1 False=0
FGIMT
Minor Alarm
Alarm Output
937 bit 6
Uint16 2
R
True=1 False=0
FGIMT
Targets
Targets Active
937 bit 7
Uint16 2
R
True=1 False=0
FGIMT
Relay Alarms
Alarm Output
937 bit 8
Uint16 2
R
True=1 False=0
FGIMT
Settings Group
SGC Auto
937 bit 9
Uint16 2
R
True=1 False=0
FGIMT
Settings Group
SGC D0
937 bit 10
Uint16 2
R
True=1 False=0
FGIMT
Settings Group
SGC D1
937 bit 11
Uint16 2
R
True=1 False=0
FGIMT
Settings Group
SGC D2
937 bit 12
Uint16 2
R
True=1 False=0
FGIMT
Settings Group
SGC D3
937 bit 13
Uint16 2
R
True=1 False=0
FGIMT
Settings Group
SGC Active Alarm
937 bit 14
Uint16 2
R
True=1 False=0
FGIMT
Settings Group
SGC Logic Override
937 bit 15
Uint16 2
R
True=1 False=0
FGIMT
Settings Group
SGC SG0
938 bit 0
Uint16 2
R
True=1 False=0
FGIMT
Settings Group
SGC SG1
938 bit 1
Uint16 2
R
True=1 False=0
FGIMT
Settings Group
SGC SG2
938 bit 2
Uint16 2
R
True=1 False=0
FGIMT
Settings Group
SGC SG3
938 bit 3
Uint16 2
R
True=1 False=0
FGIMT
50-1
Target Positive Sequence
938 bit 4
Uint16 2
R
True=1 False=0
FGIMT
50-1
67 Target Positive Sequence
938 bit 5
Uint16 2
R
True=1 False=0
FGIT
50-2
Target Positive Sequence
938 bit 6
Uint16 2
R
True=1 False=0
FGIMT
50-2
67 Target Positive Sequence
938 bit 7
Uint16 2
R
True=1 False=0
FGIT
50-3
Target Positive Sequence
938 bit 8
Uint16 2
R
True=1 False=0
FGIMT
50-3
67 Target Positive Sequence
938 bit 9
Uint16 2
R
True=1 False=0
FGIT
50-4
Target Positive Sequence
938 bit 10
Uint16 2
R
True=1 False=0
FGIMT
50-4
67 Target Positive Sequence
938 bit 11
Uint16 2
R
True=1 False=0
FGIT
50-5
Target Positive Sequence
938 bit 12
Uint16 2
R
True=1 False=0
FGIMT
50-5
67 Target Positive Sequence
938 bit 13
Uint16 2
R
True=1 False=0
FGIT
50-6
Target Positive Sequence
938 bit 14
Uint16 2
R
True=1 False=0
FGIMT
50-6
67 Target Positive Sequence
938 bit 15
Uint16 2
R
True=1 False=0
FGIT
51-1
Target Positive Sequence
939 bit 0
Uint16 2
R
True=1 False=0
FGIMT
51-1
67 Target Positive Sequence
939 bit 1
Uint16 2
R
True=1 False=0
FGIT
51-2
Target Positive Sequence
939 bit 2
Uint16 2
R
True=1 False=0
FGIMT
51-2
67 Target Positive Sequence
939 bit 3
Uint16 2
R
True=1 False=0
FGIT
51-3
Target Positive Sequence
939 bit 4
Uint16 2
R
True=1 False=0
FGIMT
51-3
67 Target Positive Sequence
939 bit 5
Uint16 2
R
True=1 False=0
FGIT
51-4
Target Positive Sequence
939 bit 6
Uint16 2
R
True=1 False=0
FGIMT
51-4
67 Target Positive Sequence
939 bit 7
Uint16 2
R
True=1 False=0
FGIT
51-5
Target Positive Sequence
939 bit 8
Uint16 2
R
True=1 False=0
FGIMT
51-5
67 Target Positive Sequence
939 bit 9
Uint16 2
R
True=1 False=0
FGIT
51-6
Target Positive Sequence
939 bit 10
Uint16 2
R
True=1 False=0
FGIT
51-6
67 Target Positive Sequence
939 bit 11
Uint16 2
R
True=1 False=0
FGIT
51-7
Target Positive Sequence
939 bit 12
Uint16 2
R
True=1 False=0
FGIT
51-7
67 Target Positive Sequence
939 bit 13
Uint16 2
R
True=1 False=0
FGIT
Alarms
Programmable Alarm 9
939 bit 14
Uint16 2
R
True=1 False=0
FGIMT
Alarms
Programmable Alarm 10
939 bit 15
Uint16 2
R
True=1 False=0
FGIMT
Alarms
Programmable Alarm 11
940 bit 0
Uint16 2
R
True=1 False=0
FGIMT
Alarms
Programmable Alarm 12
940 bit 1
Uint16 2
R
True=1 False=0
FGIMT
Alarms
Programmable Alarm 13
940 bit 2
Uint16 2
R
True=1 False=0
FGIMT
Alarms
Programmable Alarm 14
940 bit 3
Uint16 2
R
True=1 False=0
FGIMT
Alarms
Programmable Alarm 15
940 bit 4
Uint16 2
R
True=1 False=0
FGIMT
Alarms
Programmable Alarm 16
940 bit 5
Uint16 2
R
True=1 False=0
FGIMT
87N-1
Block
940 bit 6
Uint16 2
R
True=1 False=0
GT
87N-1
Pickup
940 bit 7
Uint16 2
R
True=1 False=0
GT
87N-1
Trip
940 bit 8
Uint16 2
R
True=1 False=0
GT
87N-1
Target
940 bit 9
Uint16 2
R
True=1 False=0
GT
51TF
Block
940 bit 10
Uint16 2
R
True=1 False=0
T
51TF
Pickup
940 bit 11
Uint16 2
R
True=1 False=0
T
51TF
Trip
940 bit 12
Uint16 2
R
True=1 False=0
T
51TF
Target
940 bit 13
Uint16 2
R
True=1 False=0
T
Reserved
940 bit 14
Current Demand Circuit 2
3I0 Demand Alarm
940 bit 15
Uint16 2
R
True=1 False=0
FGIMT
Current Demand Circuit 2
IP Demand Alarm
941 bit 0
Uint16 2
R
True=1 False=0
FGIMT
Current Demand Circuit 2
I2 Demand Alarm
941 bit 1
Uint16 2
R
True=1 False=0
FGIMT
Ground Current Demand Circuit 2
IG Demand Alarm
941 bit 2
Uint16 2
R
True=1 False=0
FGIMT
Local Contacts
Contact Output 6 State
941 bit 3
Uint16 2
R
True=1 False=0
FGIMT
Local Contacts
Contact Output 7 State
941 bit 4
Uint16 2
R
True=1 False=0
FGIMT
Local Contacts
Contact Output 8 State
941 bit 5
Uint16 2
R
True=1 False=0
FGIMT
Reserved
941 bit 6-8
Local Contacts
Contact Input 5 State
941 bit 9
Uint16 2
R
True=1 False=0
FGIMT
Local Contacts
Contact Input 6 State
941 bit 10
Uint16 2
R
True=1 False=0
FGIMT
Local Contacts
Contact Input 7 State
941 bit 11
Uint16 2
R
True=1 False=0
FGIMT
Reserved
941 bit 12-942 bit 5
Analog Input Protection 1
Block
942 bit 6
Uint16 2
R
True=1 False=0
FGIMT
Analog Input Protection 1
Pickup
942 bit 7
Uint16 2
R
True=1 False=0
FGIMT
Analog Input Protection 1
Trip
942 bit 8
Uint16 2
R
True=1 False=0
FGIMT
Analog Input Protection 1
Target
942 bit 9
Uint16 2
R
True=1 False=0
FGIMT
Analog Input Protection 2
Block
942 bit 10
Uint16 2
R
True=1 False=0
FGIMT
Analog Input Protection 2
Pickup
942 bit 11
Uint16 2
R
True=1 False=0
FGIMT
Analog Input Protection 2
Trip
942 bit 12
Uint16 2
R
True=1 False=0
FGIMT