Hardware Preparation and Installation

MVME6100 Single Board Computer Installation and Use (6806800D58H)

27

The following illustration shows jumper setting options for J30. The factory default is shown
where applicable:

Refer to

Front/Rear Ethernet and Transition Module Options Header (J30)

on page 103

for

connector pin assignments.

1.5.5

SROM Configuration Switch (S3)

A part of the 8-position SMT switch, S3 enables/disables the MV64360 SROM initialization and
all I

2

C EEPROM write protection.

The SROM Init switch is OFF to disable the MV64360 device initialization via the I

2

C SROM. The

switch is ON to enable this sequence.

Figure 1-5

Front/Rear Ethernet Option Settings