Table 2-3 AC System Power Requirements
Feature
Value (For AC)
Rated voltage and input current
100 VAC to 240 VAC and 8.5 A Max
Operating voltage range
90 VAC to 254 VAC
Table 2-4 DC System Power Requirements
Feature Value
Rated voltage and input current
-48 VDC to -60 VDC, 18 A to 15 A
US and Canada: -48 VDC, 18 A
Operating voltage range
-40.0 VDC to -72 VDC
US and Canada: -40.0 VDC to -60 VDC
Maximum power dissipation
The power distribution is tested for
supplying 320 W/front slot to all slots
simultaneously and additionally 35
W/rear slot.
User card power requirement
max. 8W