1 ac psu input power requirements, Table 7-1, Ac psu input power requirements – Artesyn Centellis 2000 Shelf Release 3.0 Installation and Use (May 2014) User Manual
Page 144: Power subsystem

Power Subsystem
Centellis 2000 Shelf Release 3.0 Installation and Use (6806800L99G)
144
7.2.4.1
AC PSU Input Power Requirements
The following table lists the PSU input power requirements:
Table 7-1 AC PSU Input Power Requirements
Feature
Value
Input Voltage Range
90 VAC to 254 VAC (Universal Input)
Input Nominal Line
Voltages
100 VAC to 240 VAC, 50 Hz to 60 Hz
Frequency Range
47 Hz to 63 Hz
Leakage Current
Maximum of 3.5 mA
Power Factor
Minimum of 0.98 at full load and nominal line
Harmonic Content
As per EN61000-3-2, 1995 Version, Sections 5 and 7
Efficiency
Better than 85% at nominal line and load between 50 and 100%
Better than 80% across the operation voltage range, at loads
between 50 and 100%
In Rush Current
At insertion of a PSU with AC voltage available at the hot-plug
connector, the charging of input capacitance or converter startup
current shall not lead to arcing or any damage of the hot-plug
connector pin’s (see also 4.2.16 hot-swap operation)
Isolation
Primary-secondary and primary to ground (PE) isolation shall
follow EN60950 and harmonized international applicable
standards.
AC PSU input is fused at 16A. External wiring and circuit interruption should be sized
accordingly.