1 ipmi firmware upgrade, Software – Artesyn Centellis 2000 Shelf Release 3.0 Installation and Use (May 2014) User Manual
Page 179
Software
Centellis 2000 Shelf Release 3.0 Installation and Use (6806800L99G)
179
Please refer to the Release Notes to find out about software dependencies.
11.2.2.1 IPMI Firmware Upgrade
Centellis 2000 Fan Tray IPMI Firmware:
The fcu utility can be used to upgrade the Centellis 2000 Fan tray with the following syntax:
fcu -t
The ipmb_addr parameter is c8 for the rear fan tray, or ca for the front fan tray. For example:
fcu -tc8 -uvf /root/ root/C2000_Fantray-upgrade-1_04_145.hex
fcu -tca -uvf /root/ root/C2000_Fantray-upgrade-1_04_145.hex
Centellis 2000 10G Telco Alarm User Card IPMI Firmware:
The fcu utility can be used to upgrade the Centellis 2000 10G Telco Alarm User Card with the
following syntax:
fcu -t
1_04_003.hex
The ipmb_addr parameter is d0 for the upper User Card, or d2 for the lower User Card. For
example:
fcu -td0 -uvf /root/C2000_10G_ALARM_USERCARD-upgrade-1_04_003.hex
fcu -td2 -uvf /root/C2000_10G_ALARM_USERCARD-upgrade-1_04_003.hex
BBS software upgrade on any
blade
-
Install the files of the new software version as
described in the Basic Blade Services Software
Programmer’s Reference of the respective blade
Chapter: Installation
Node blade firmware upgrade
Depends on the node blade. Please refer to the documentation of
the respective blade.
Table 11-2 Available Software Upgrade Tools (continued)
Procedure
Tool
Document/Chapter