Network management and system access – Artesyn Centellis 2000 Shelf Release 3.0 Installation and Use (May 2014) User Manual
Page 155

Network Management and System Access
Centellis 2000 Shelf Release 3.0 Installation and Use (6806800L99G)
155
Virtual Standby IP Address on Out-of-Band Interface
To avoid an address conflict between out-of-band and backplane interfaces, 100 is added to
the third octet of all out-of-band interface IP addresses, if any of them would be equal to one of
the backplane addresses otherwise.
Changing the Shelf Manager Virtual IP Address for the Out-of-Band Interface
To change the Shelf Manager Virtual IP address:
Modify the first two octets of the shelf IP connectivity Record #1
or
Change the shelf address
or
Modify the first two octets of the shelf IP connectivity Record #1 and also change the shelf
address
Setting the Shelf Geographical Address
, to see how you can change the shelf
address.
1. Change the first two octets of the IP address using the hpiship tool located on the
shelf manager. Use the option -h for help.
2. Change the third octet of the IP address by changing the shelf address.
3. Reboot the system for the changes to take effect.
Netmask of IP1
Virtual Standby IP Address
Default Value
255.0.0.0
192.168.0.181
255.255.0.0
255.255.255.0
If the third octet of the IP address is changed using hpiship, it is temporary and will be
changed automatically on the next reboot to match the shelf address.