6 replacing dc power entry modules, Replacing dc power entry modules – Artesyn Centellis 2000 Shelf Release 3.0 Installation and Use (May 2014) User Manual
Page 108
FRU Installation
Centellis 2000 Shelf Release 3.0 Installation and Use (6806800L99G)
108
9. Check the PSU Status LED and take the appropriate actions as listed in the table
below.
10.Switch the external disconnect device to the ON position.
11.Verify that the green PSU LED is lit.
4.6
Replacing DC Power Entry Modules
This section provides the information needed to replace the power entry modules (PEMs).
PSU Status LED
Status
LED (red) off
Reason: The power is disconnected.
Action: Turn off the feed power and attach the power cables at the
power connector.
LED (red) on
LED (green) off
Power supply is in a failed state.
LED (red) off
LED (green) on
The power is connected correctly.