Example #1:
Print current IP address settings and change out-of-band address:
*Print current IP address settings
shm9s8:~ # hpiship
29 {ADVANCEDTCA_CHASSIS,9} Shelf Resource
4097 Shelf Manager IP Address 0
IP : 192.168.9.171
Gateway: 192.168.9.0
Submask: 255.255.255.0
8449 Shelf Manager IP Address 1
IP : 172.16.9.171
Gateway: 172.16.0.170
Submask: 255.255.0.0
*Change out-of-band-address:
shm9s8:~ # hpiship -n 4097 -i 200.200.0.0
Example #2:
Print current shelf address and shelf entity path setting, and then change shelf address and
shelf entity path settings:
*print current Shelf Address and Shelf Entity Path setting:
shm9s8:~ #hpishaddr
shelf address type=BINARY, length=20: 09 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00
shelf id: 9
shelf entity-path: {ADVANCEDTCA_CHASSIS,9}