beautypg.com

1 base interface, Figure 5-1, Location of zones on a blade – Artesyn Centellis 2000 Shelf Release 3.0 Installation and Use (May 2014) User Manual

Page 132

background image

Non-Field-Replaceable Units

Centellis 2000 Shelf Release 3.0 Installation and Use (6806800L99G)

132

These interfaces are connected to the slots/blades across the connectors forming the zone 2.
Respective zones are on the AdvancedTCA blade.

5.2.1

Base Interface

The base interface is configured as a dual star in an Ethernet network environment. The two Gb
Ethernet hubs integrated in the MF106 provide redundant network connection via the base
interface. The base interface is routed from each of the hubs to both blades in the shelf in dual
star topology. The protocol is 10/100/1000 BaseT Ethernet. Connections are composed of four
differential signal pairs (one row) called base channel (of the zone 2 connector).

The base interface is fully compliant to the PICMG 3.0 R3.0 Specification. Therefore, details are
not described within this chapter.

For more information, see the MF106 Installation and Use and the PICMG 3.0 R3.0 Specification.

Figure 5-1

Location of Zones on a Blade