Note 1) – Altera External Memory PHY Interface User Manual
Page 27

Chapter 3: Functional Description—ALTMEMPHY (nonAFI)
3–11
ALTMEMPHY Signals
© January 2010
Altera Corporation
External Memory PHY Interface (ALTMEMPHY) (nonAFI) Megafunction User Guide
The ports in
exists for all DDR2/DDR SDRAM variations.
aux_full_rate_clk
output
1
A copy of the mem_clk_2x signal that you can use in
other parts of your design.
Note to
(1) Refer to
for the reset mechanism in Arria GX, Cyclone III, Stratix II and Stratix II GX devices.
Table 3–2. Clock and Reset Signals for DDR2/DDR SDRAM—nonAFI
(Note 1)
(Part 2 of 2)
Signal Name
Type
Width
Description
Table 3–3. PLL Reconfiguration Signals for DDR2 and DDR SDRAM—nonAFI
Signal Name
Type
Width
Description
pll_reconfig_
enable
input
1
Allows access to the PLL reconfiguration block. Hold this
signal low in normal operation. While the ALTMEMPHY is held
in reset (via the soft_reset_n signal), and the
reset_request_n
signal is 1, it is safe to reconfigure the
PLL. To reconfigure the PLL, set this signal to 1 and use the
other pll_reconfig signals to access the PLL. When
finished reconfiguring, set this signal to 0, and then set the
soft_reset_n
signal to 1 to bring the ALTMEMPHY out of
reset. For this signal to work, the
PLL_RECONFIG_PORTS_EN
parameter must be set to
TRUE
.
pll_reconfig_
write_param
input
1
For more information, refer to the
pll_reconfig_read
_param
input
1
For more information, refer to the
pll_reconfig
input
1
For more information, refer to the
pll_reconfig_
counter_type
input
4
For more information, refer to the
pll_reconfig_
counter_param
input
3
For more information, refer to the
pll_reconfig_data
_in
input
9
For more information, refer to the
pll_reconfig_soft
_reset_en_n
input
1
The asynchronous reset input to the PLL reconfiguration
block. This reset causes a PLL reconfiguration block reset and
holds the reset if the ALTMEMPHY megafunction in reset while
the signal is low. This port only exists in the DDR2/DDR
SDRAM variation for Arria GX, Stratix II, and Stratix II GX
devices.
pll_reconfig_busy
output
1
For more information, refer to the
pll_reconfig_data
_out
output
9
For more information, refer to the
pll_reconfig_clk
output
1
Synchronous clock to use for any logic accessing the PLL
reconfiguration interface.
pll_reconfig_
reset
output
1
Resynchronized reset to use for any logic accessing the PLL
reconfiguration interface.