2 safe actuator with two encoders, Safe actuator with two encoders – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 90

background image

Technical details

Operating Manual PMCprotego S1­2(­C)
1002528­EN­02

90

The safety­related characteristic data is valid for all safety functions.

All the units used within a safety function must be considered when calculating the safety
characteristic data.

9.1.2

Safe actuator with two encoders

Operating
mode

EN ISO
13849­1:
2008

PL

EN ISO
13849­1:
2008

Category

EN IEC
62061

SIL CL

EN IEC
62061

PFH

D

 [1/h]

IEC 61511

SIL

IEC 61511

PFD

EN ISO
13849­1:
2008

T

M

 [year]

Safe actu­
ator

PL e

Cat. 4

SIL CL 3

1,46E­08

SIL 3

4,72E­04

20

The safety analysis of the plant or machine may necessitate a second encoder (external
encoder). Example: Fault detection in the mechanical transmission path between motor and
process.

The sensor subsystem consists of the motor encoder (sensor 1) and an external encoder
(sensor 2). A separate PL or SIL must be calculated for this subsystem. For this subsystem
structure, Category 3 with a DC of 99 % is acceptable. The following characteristic data is
required for both sensors (motor encoder and external encoder): MTTF

d

 and λ

d

 /λ.

Subsystem

Safe actuator

Subsystem

Sensor

Sensor 1

Motor encoder

Sensor 2

External encoder

Diversity
with cross-
comparison

PMCprotego D
PMCprotego S1

The safety­related characteristic data is valid for all safety functions.

All the units used within a safety function must be considered when calculating the safety
characteristic data.

This manual is related to the following products: