beautypg.com

Download configuration from sd card to safety card – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 78

background image

Commissioning

Operating Manual PMCprotego S1­2(­C)
1002528­EN­02

78

7.3.3.3

Download configuration from SD card to safety card

Before carrying out the steps described in this section, please note the following safety
guidelines:

CAUTION!

Make absolutely sure that the SD card with the safety card configuration is
inserted into the read device of the correct servo amplifier. If not, invalid
parameter settings (e.g. limit values) may lead to unexpected movements
and hazardous situations for either people or equipment.

When the configuration is downloaded from the SD card, the servo amplifier
does not check the safety card configuration, nor does it check that the con­
figuration is assigned correctly to a specific safety card.

After swapping the safety card, check that the safety functions are activated
correctly.

4

 The safety card's configuration data can be downloaded to the safety card from an SD

card inserted in the servo amplifier, without using the Configurator.

During this process, the firmware for the servo amplifier is also reloaded.

Prerequisite:

}

The following files must be available on the SD card (

3

 or 

6

):

default.pdis: Configuration file for the safety card

default.bin or default.s19: Firmware for the servo amplifier

default.par: Parameter file for the servo amplifier

Procedure:

1. Switch off the 24 V supply to the servo amplifier.

2. Insert the SD card into the read device in the servo amplifier.

3. Keep both operator keys 

 on the servo amplifier pressed down.

4. Switch on the 24 V supply to the servo amplifier.

5. Release the keys when "­" appears on the display.

6. Press both operator keys 

 again and then release them.

The firmware update for the servo amplifier is started.

The file default.bin or default.s19 is loaded.

Display: Counts from 0 to 100, stops at 100 and then counts from 100 to 0.

The servo amplifier is restarted. The parameter file default.par is loaded.

The safety card is restarted: The "CONFIG" LED flashes.

7. Wait until "dis" (= drive integrated safety) appears on the display.

a Note: You must then press the left­hand operator key on the servo amplifier within

60 seconds (see step 8).

This manual is related to the following products: