beautypg.com

2 dual-pole outputs, 3 output test, Dual­pole outputs – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 18: Output test

background image

Function description

Operating Manual PMCprotego S1­2(­C)
1002528­EN­02

18

}

“1” signal (+24 V) at the output:

Output is low impedance

Current is supplied to the load

Safety function activated

Supply voltage

}

24 VDC connection to supply the safety card's digital outputs

4.2.2.2

Dual­pole outputs

The safety card has a safe dual­pole output to control a mechanical brake:

}

SBC+/SBC­

Signals at the output

}

“0” signal (0 V) at the output (SBC+/SBC­):

Output is high impedance

No current to the load

Safety function is activated, brake closed

}

“1” signal (+24 V) at the output (SBC+/SBC­):

Output is low impedance

Current is supplied to the load

Safety function is not activated, brake open

NOTICE

Only a brake which operates in accordance with the failsafe principle may
be connected.

Supply voltage

}

24 VDC connection to supply the safety card's digital outputs

4.2.2.3

Output test

The outputs are tested regularly:

}

Outputs that are switched on are checked via regular off tests.

Test pulses for outputs that are switched on: see technical details

Outputs that are switched on are switched off for the duration of the test pulse.

The load must not switch off because of the test.

}

Outputs that are switched off are checked via regular on tests.

Test pulses for outputs that are switched off: see technical details

Outputs that are switched off are switched on for the duration of the test pulse.

The load must not switch on because of the test.

Testing for shorts

}

A test is regularly carried out to check for shorts between the outputs.