Function description

Operating Manual PMCprotego S1­2(­C)
1002528­EN­02

38

Timing diagram:

STO delay time

Tolerance window

SS1 Activate

SS1 SIL3/Reset

Ready

STO Acknowledge

SDI Neg Activate

SDI Pos Activate

SDA Safe Direction
Acknowledge

Fig.: Safety function SDI

}

t

1

: Activation of safety function SDI

}

t

2

: Once the SDI delay time has elapsed, the direction of rotation is monitored

}

SS1 Activate: Input for safety function SS1

}

SS1 SIL3/Reset: Input for SIL 3 and reset

}

SDI Pos Activate: Input for safety function SDI, positive direction is monitored

}

SDI Neg Activate: Input for safety function SDI, negative direction is monitored

}

Ready: Output for operating status of safety card and second output for feedback from
safety function STO

}

STO Acknowledge: Output for feedback from safety function STO

}

SDA Safe Direction Acknowledge: Output for feedback from safety function SDI

Switching the direction of rotation while safety function SDI is active

}

When changing the direction of the motor, please note: Monitoring of the old direction
must be deactivated first, before monitoring of the new direction of rotation is activated!
(See Case A in the illustration). If an SDI delay time t

m

 has been configured, it will start

when the new direction of rotation monitoring is activated. In A, the SDI delay time t

m

 is

shown = 0.