beautypg.com

Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 40

background image

Function description

Operating Manual PMCprotego S1­2(­C)
1002528­EN­02

40

Timing diagram:

v

t

SS1 SIL3/Reset

1

0

1

0
1

0

1

0

1

0

SS1 Activate

Ready

STO Acknowledge

SDI

1

0

SDA Safe Direction
Acknowledge

SDI Neg Activate

1

0

SDI Pos Activate

t1

t2

Tolerance window

SDI

SDI delay time

Fig.: Changing the direction of rotation with SDI delay time.

}

t

1

: Activation of safety function SDI in negative direction of rotation

}

t

2

: Once the SDI delay time has elapsed, the negative direction of rotation is monitored

}

SS1 Activate: Input for safety function SS1

}

SS1 SIL3/Reset: Input for SIL 3 and reset

}

SDI Neg Activate: Input for safety function SDI, negative direction is monitored (new dir­
ection of rotation)

}

SDI Pos Activate: Input for safety function SDI, positive direction is monitored (old dir­
ection of rotation)

}

Ready: Output for operating status of safety card and second output for feedback from
safety function STO

}

STO Acknowledge: Output for feedback from safety function STO

}

SDA Safe Direction Acknowledge: Output for feedback from safety function SDI

This manual is related to the following products: