beautypg.com

3 safety functions, 1 safe torque off - sto, Safety functions – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 20: Safe torque off ­ sto

background image

Function description

Operating Manual PMCprotego S1­2(­C)
1002528­EN­02

20

4.3

Safety functions

Safety functions maintain a safe condition on a plant or prevent hazardous conditions
arising on a plant.

The safety functions for electrical drives are defined in EN 61800­5­2.

The safety card implements the following safety functions:

}

Safe stop 1 (SS1)

}

Safe stop 2 (SS2)

}

Safe operating stop (SOS)

}

Safe speed range (SSR)

}

Safely limited speed (SLS)

}

Safe direction (SDI)

}

Safely Limited Increment (SLI)

}

Safely Limited Position (SLP)

}

Safe brake control (SBC)

}

Safe brake test (SBT) (not defined in EN 61800­5­2)

Activation of safety functions

}

The safety functions are activated using the single­pole safe inputs on the safety card.

}

These inputs operate in accordance with the failsafe principle (on switching off). The
safety control system activates the safety functions via a 1/0 pulse edge.

Feedback from the safety functions

}

Message via single­pole semiconductor outputs

“1” Signal: Inside the set limit values

“0” Signal: Outside the set limit values

Simultaneous activation of safety functions

}

All safety functions can be active at the same time. However, safety function SS1 has
priority over all other safety functions.

}

If SS1 is activated, the drive is stopped in accordance with its configuration.

}

No other safety functions are processed or called up during this time.

Reaction to limit value violations and errors

}

When set limit values are exceeded, the E­STOP braking ramp is activated.

}

The safety function STO is activated if there are any internal errors on the safety card
or servo amplifier. The power element is switched off.

4.3.1

Safe Torque Off ­ STO

The safety function "Safe Torque Off" (STO) removes the power to the motor. It is imple­
mented via the servo amplifier's shutdown path and the safety card's safe outputs.

Features of the safety function:

}

The motor becomes torque­free and no longer generates any hazardous movements.

}

To prevent the drive running down in an uncontrolled manner, in normal operation the
safety function STO is activated via the safety function SS1.