Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-7

6.2

Preparing for operation

6

Commissioning

6.2.5

Connection of two base units

Connection of two base units

6-

6.2.5.1

Interface assignment

Interface assignment

6-

Schnittstellenbelegung_8-polig_mml1p

6.2.5.2

Connection

Connection

6-

Betriebsbereitschaft herstellen Anschluss

Connection of two base units PNOZmulti Mini via the integrated interface

RJ45 socket
8-pin

PIN

Layout

1

CA+

2

CA-

3

CB+

4

n.c.

5

n.c.

6

CB-

7

n.c.

8

n.c.

Shield

CGround

8 1

CA+
CA-
CB+
CB-

CGround

CA+
CA-
CB+
CB-

PNOZ mm0.2p

PNOZ mm0.2p

1

2

3

6

CGround

This manual is related to the following products: