2 block diagram, 3 connection of two base units, 4function description – Pilz PNOZ mm0.2p User Manual
Page 18: 1 device properties
4.1
Device properties
4
Function description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-2
4.1.2.2
Block diagram
Block diagram
4-
Blockschaltbild PNOZ mm0.2p
4.1.2.3
Connection of two base units
Connection of two base units
4-
Funktionen_multi_Verbindungsschnittstelle_1
The integrated interface for connection of 2 base units is used to safely
transfer the input information from 32 virtual inputs and 32 virtual out-
puts between two PNOZmulti systems.
Each base unit needs either an integrated interface or a link module for
the connection.
Funktionen_multi_Verbindungsschnittstelle_2
Data exchange:
Data is exchanged cyclically.
At the end of the PNOZmulti cycle, each base unit sends its output
data to the other base unit or to the link module on the other base unit.
At the same time the base unit reads the input data from the other
base unit.
=
Power
A1 A2
=
Input
Configurable
output
24 V 0 V
24 V 0 V
T0M21
O2
O0 O1
O3
IM1
I8
I5
I11
I4
I9
I12 I13 I14 I15
I7
I6
I10
IM2
IM0
IM3IM16
IM18
IM17
IM19
Interface extension module
USB
Interface extension module
Configurable
input/output
T0M22 T0M23
T0M20
CA+ CA- CB+ CB- CGround
RJ45
Safe Link Interface