Introducing the Smart User Interface

44

FTB-8500 Series and FTB-8120NGE/8130NGE

Global Test Status and Controls

Load

b

: Loads a previously saved configuration. Select an existing file and press

Open to confirm. The default directory is

d:\ToolBox\User Files\PacketBlazerG2\Configuration. The configuration file

extension is cfg.
An error message is displayed and the configuration is not loaded when the file

is corrupted, the module is not properly installed, the hardware or software

options are not compatible, or when the resources or power are not sufficient.
Save

b

: Saves the current test configuration. Select an existing file, or type a new

name in the File name field, and press Save. The default directory is

d:\ToolBox\User Files\PacketBlazerG2\Configuration.
Send

a

: Generates pattern bit error according to the amount selected on the

Pattern TX tab. Refer to Pattern Error Injection on page 254. This button is only

available with BERT test.
Set

a

: Allows selecting the port that will be used for pattern bit error injection.

See Send button for error injection. This button is only available with BERT test

in Dual Ports topology. Available with FTB-8510B only.
Laser Off (grey): Indicates that the laser control is off. Pressing this button will

activate the laser immediately by emitting an optical laser signal. This button is

only available for optical interfaces. The laser is On by default when the test is

created unless otherwise set from the Default/Ethernet Test Preferences on

page 368.
Laser On (green): Indicates that the laser control is on. Pressing this button will

turn off the laser. This button is only available for optical interfaces. The laser is

On by default when the test is created unless otherwise set from the
Default/Ethernet Test Preferences on page 368. The laser control button is not

affected when turning off the laser by generating a LOS for example.
Favorites

b

: Provides access to 10 default or customer defined test case

configurations. See Favorites on page 46 for more information.

a.

Only available when the test is running.

b.

Only available when the test is not running (Stop).