beautypg.com

EXFO FTB-8500 Series for FTB-500 User Manual

Page 219

background image

Stream Generation Tabs

Ethernet and Fibre Channel Application

205

Overview

Data Link: Select the data link type (layer 2). Choices are
Ethernet II and 802.3 SNAP.

Note: Network, and Transport are not available with RFC 2544 test. Only data

link frame size is available with BERT - Framed Layer 1 test.

Network: Select the network traffic type (layer 3). Choices are IPv4
or IPv6, and None. The default setting is IPv4.

Transport: The Transport is set to UDP. Transport is automatically
disabled when Network is set to None.

Size: Select the frame size for each traffic type.

For Framed Layer 1, only the Data Link is configurable from 48 to
10000 for 10Mbps, and 16000 for 100Mbps/1000Mbps/10Gbps.

For Framed Layer 2, choices are:

Traffic Type

Frame Size

Minimum

Maximum

10 Mbps

100/1000 Mbps

and 10 Gbps

Data Link

48

a

a.

The minimum frame size will be adjusted according to the frame structure and

components selected.

10000

16000

Network

46

a

9982

15982

Transport

UDP

TCP

26

a

38

a

9962

15962

This manual is related to the following products: