Field match configuration, Filter configuration – EXFO FTB-8500 Series for FTB-500 User Manual
Page 520
Pop-Up Windows
506
FTB-8500 Series and FTB-8120NGE/8130NGE
Field Match Configuration
Field Match Configuration
This pop-up window is only available from Traffic Analyzer - Capture tab.
Allows to define the trigger criteria that will be used to automatically start
the capture when a received frame matches the trigger’s criteria.
Filter Configuration
“(“ and “)“: The open and close parenthesis may be useful to control the
precedence of operands when more than two operands are used. Only
one level of parenthesis is supported. When no parenthesis are used, a
logical AND will have precedence over a logical OR.
Not: When selected, add the logical negation (not equal) operator for the
operand filter defined at its right.
Filter: Allows the selection of the filter to be used. The default setting is
None. See Filter on page 176 for the filter list.
Value: Allows entering the value associated to the selected filter. See
Overview on page 200 for more information on possible values.