EXFO FTB-8500 Series for FTB-500 User Manual
Page 328
RFC 2544 Tabs
314
FTB-8500 Series and FTB-8120NGE/8130NGE
Frame Loss
Frame Loss Results
Frame Size: Indicates the frame sizes used for the test. Up to seven
different frame sizes can be displayed.
Note: The “--” indicates that the result is not available because the test has not
run yet or the measured value is not valid.
TX-to-RX/Local to Remote/Remote to Local: Gives the number of
frames for the corresponding direction. P1-to-P2/P2-to-P1 is only
available with FTB-8510B.
Current Trial: Indicates the current trial number.
Current Step: Indicates the current percentage of the testing rate.
Units: Indicates the throughput result unit which is % Loss.
Displayed Step: Indicates what TX-to-RX/Local to
Remote/Remote to Local rate result is displayed. This setting is
only available when the test is running or completed.
P1-to-P2/P2-to-P1 is only available with FTB-8510B.
Displayed Results: Select the displayed result mode: Current,
Minimum, Maximum, or Average. The default setting is Current.