Service configuration test (results) – EXFO FTB-8500 Series for FTB-500 User Manual
Page 359
EtherSAM Tabs
Ethernet and Fibre Channel Application
345
Service Configuration Test (Results)
Service Configuration Test (Results)
Press TEST, EtherSAM Results, and Service Configuration Test.
Service No allows the selection of the service number.
Service name indicates the name of the selected service number.
Service Verdict indicates the pass
or fail verdict for the selected
service, including metrics and maximum throughput, once all the
ramp steps and burst tests have been performed on this service.
Max RX Rate indicates the measured maximum utilization throughput.
The verdict is also displayed indicating if the maximum throughput
complies (pass
) or not (fail ) to the maximum allowed value
based on either the configured CIR+EIR or CIR when CIR+EIR is not
enabled.
Max RX Rate R-> L and Max RX Rate L-> R, for dual test set, indicates
respectively the average of the measured maximum throughput for the
entire configuration test from remote to local and local to remote unit.