Stream Generation Tabs

Ethernet and Fibre Channel Application

207

Stream Configuration

Stream Configuration

Press TEST, Stream Gen, and Stream Config.

Stream No.

For Frame Analyzer, select the stream number from the list. Only stream
number 1 is available for BERT test.

Stream Profile

Note: For Frame Analyzer test only, allows to emulate Voice (

), Video (

), or

Data (

) streams. The default setting is Data.

For Voice:

Voice Codec: Choices are VoIP G.711, VoIP G.723.1, and VoIP G.729.
The default setting is VoIP G.711.

Nb Calls: Allows the selection of the equivalent number of calls that
will be generated for the selected stream. The default setting is 1.