Creating and Starting a Test Case
108
FTB-8500 Series and FTB-8120NGE/8130NGE
Ethernet Smart Loopback Test Case
1f. For FTB-8510B, select the
port number by pressing
on Port 1 or Port 2.
For FTB-8510B in Dual
Ports, select the first port
and proceed with the rest
of the configuration for the
first port. However, before
pressing Finish, press
Back several times to
return to the port setup
window, select the second
port and proceed with the
rest of the configuration for the second port.
1g. For Electrical RJ-45, if required, select
the Ethernet port crossover check box
to inverse the pin-to-pair assignment of
the UTP cable used.
Note: At this point you should have a link up indicated in the Tree view tab. A
green LED indicates a link up while a red LED indicates a link down. For
electrical port, if the link is down, make sure that the Ethernet port
crossover setting is correct.
1h. Press Next.