beautypg.com

Calculate[1..n][:wdm]:data:channel: osnr – EXFO FTB -5240S/5240BP Optical Spectrum Analyzer User Manual

Page 491

background image

SCPI Command Reference

OSA

485

Product-Specific Commands—Description

:CALCulate[1..n][:WDM]:DATA:CHANnel:

OSNR?

Description

This query returns computed WDM analysis

result for signal-to-noise ratio of the selected

channel.

At *RST, this value is not available.

Syntax

:CALCulate[1..n][:WDM]:DATA:CHANnel:OSNR?

Parameter(s)

None

Response Syntax

Response(s)

Osnr:
The response data syntax for is defined

as a

element.

The response corresponds to the

computed signal-to-noise ratio.

Example(s)

CALC:CHAN:DEL:ALL

CALC:CHAN:DEF "ITU_017", 203.8950 THZ

CALC:CHAN:SEL "ITU_017"

CALC:CHAN:SIGP:TYPE IPOW

CALC:CHAN:NOIS:AUTO OFF

CALC:CHAN:NOIS:TYPE IEC