beautypg.com

Calculate[1..n][:wdm]:channel: noise:auto – EXFO FTB -5240S/5240BP Optical Spectrum Analyzer User Manual

Page 428

background image

SCPI Command Reference

422

FTB-5240S/S-P/BP

Product-Specific Commands—Description

Example(s)

CALC:WDM:CHAN:DEF "C_001",192.1750 THZ

CALC:WDM:CHAN:SEL "C_001"

CALC:WDM:CHAN:NOIS:AUTO ON

CALC:WDM:CHAN:NOIS:AUTO? Returns 1 (auto

noise enabled)

Notes

Auto noise is available only if software option

"InB" is active.

Auto noise is computed only if analysed trace

was acquired using PMMH averaging type.

See Also

:CALCulate[1..n][:WDM]:CHANnel:AUTO:NOISe:

AUTO

:CALCulate[1..n][:WDM]:CHANnel:NOISe:TYPE

:CALCulate[1..n][:WDM]:CHANnel:NOISe:AUTO?

:CALCulate[1..n][:WDM]:CHANnel:SELect

:SENSe[1..n]:AVERage:TYPE

:CALCulate[1..n][:WDM]:CHANnel:

NOISe:AUTO