Jt25 operator’s manual – Ditch Witch JT25 User Manual
Page 29
Controls - 28
JT25 Operator’s Manual
Left Control Console
Most engine display functions are self-explanatory. For more information about functions, see the
manufacturer’s instructions at www.fwmurphy.com.
Main Menu
4.
Engine coolant
temperature gauge
Displays engine coolant
temperature.
Normal coolant temperature is 160°-
212° F (71°-100° C).
5.
Hour meter
Displays number of hours
engine has been running.
6.
Engine oil pressure
gauge
Displays engine oil pressure.
Full load reading should be 60-80 psi
(4.1-5.5 bar).
7.
Soft key
Press to select a soft key
command.
Soft key commands change with each
menu screen and are displayed next
to the key.
8.
Soft key
9.
Main menu key
Press from main screen
(gauges) to select main
menu.
10. Soft key
Press to select a soft key
command.
Soft key commands change with each
menu screen and are displayed next
to the key.
11. Day/Night mode key
Press from main screen
(gauges) to toggle between
day and night modes.
12. Voltmeter display
Shows system voltage.
Normal voltage is 13-14V with engine
running.
IMPORTANT: Soft key commands change with each menu screen and are displayed next to the key.
Item
Description
Notes
11. System settings key
Press to select system
settings menu.
System settings menu displays
information about the system.
Diagnostic information is only
available to dealer technicians.
10. User settings key
Press to select user settings
menu.
User settings menu allows user to
change the language and unit
settings, and to set the time and date.
9. Main screen key
Press to return to main
screen (gauges).
8. Engine diagnostics key
Press to select engine
diagnostics menu.
For dealer technician use only.
Item
Description
Notes