Jt25 operator’s manual – Ditch Witch JT25 User Manual
Page 182
JT25 Operator’s
Manual
Service - 181
500 Hour
CMW
Change Fuel Filters
Replace fuel filters every 500 hours. See parts
manual or contact your Ditch Witch dealer for
correct replacement filter.
Check Batteries
Check batteries every 500 hours. Keep batteries
clean and terminals free of corrosion.
To clean:
1.
Turn battery disconnect switch to the off
position.
2.
Ensure that no ignition sources are near
batteries.
3.
Loosen and remove battery cable clamps
carefully, negative (-) cable first.
4.
Clean cable clamps and terminals with wire
brush or battery cleaning tool to remove dull
glaze.
5.
Check for signs of internal corrosion in cables.
6.
Apply MPG to terminals after cleaning to reduce corrosion.
7.
Connect battery cable clamps, positive (+) cable first.
8.
Tighten any loose connections.
9.
Ensure that battery tiedowns are secure.
10. Turn battery disconnect switch to the on position.
Explosion possible. Serious injury or equipment damage could occur.
Follow directions carefully.
NOTICE: To avoid explosion, do not create sparks and do not short across battery
terminals for any reason.
j37om034h.eps
j37om034h.eps
j37om035h.eps
j37om035h.eps