Systems and Equipment - 114

JT25 Operator’s Manual

Electric Strike System

CMW

Strobe light on drilling unit
does not work during total
test

Improper connections with
control module

Check connections and wiring
harness

Defective strobe light

1.

Disconnect strobe and connect to
external 12V power source.

2.

If strobe does not work, replace it.

Defective control module

Have control module checked or
replaced

Alarm on drilling unit does
not work during total test

Improper connections with
control module

Check connections and wiring
harness

Defective alarm

1.

Disconnect strobe and connect to
external 12V power source.

2.

If strobe does not work, replace it.

Defective control module

Have control module checked or
replaced

Strobe light and alarm on
drilling unit do not work
during total test

Improper connections with
control module

Check connections and wiring
harness

Defective control module

Have control module checked or
replaced

EC2 code displays and
current problem indicator is
on

Improper connections with
control module

Check cable connections on control
module and current transformer

Defective current transformer

1.

Disconnect current transformer.

2.

Check for 20-40 ohms from pin 1
to pin 4, 20-40 ohms from pin 1 to
pin 2, and less than 1 ohm from
pin 2 to pin 4.

Defective current transformer
cable

1.

Disconnect cable from
transformer and control module.

2.

Check continuity of cable.

3.

If continuity is zero or cable is
damaged, replace.

Defective control module

Have control module checked or
replaced

EV2 code displays and
voltage problem indicator is
on

Improper connections with
control module

Check cable connection on control
module

Defective voltage limiter

Have voltage limiter checked or
replaced

Defective control module

Have control module checked or
replaced

Problem

Possible cause

Possible solution