Appendix A: Wiring
RMC100 Startup Guide
36
deltamotion.com
Wiring the Analog Feedback Module
Voltage Feedback Transducers
Voltage feedback transducers can be connected directly to the +In and -In
connections for the desired channel. The Res connection is unused for voltage
transducers. The following configuration is recommended:
TIP: If you are using a 10V transducer output, but are only using values in the low
5V, it is recommended that you select a 5V setting to increase the resolution of the
analog to digital conversion.
Current Feedback Transducers
Current feedback transducers are connected in the same way as voltage transducers
except that a jumper must be inserted between the +In and Res connections. This
places a resistor internal to the RMC across the two inputs, thus converting the
current to a voltage input. The following wiring diagram shows a suggested
configuration: