Communications choices, Ethernet (-enet) – Delta RMC101 User Manual
Page 24
RMC100 Modules
RMC100 Startup Guide
24
deltamotion.com
Communications Choices
The versatile RMC100 Motion Controllers can be configured with one of five
different communication modules supporting more than 25 protocols. The bus-
based communication modules are not just for motion data acquisition—they
support full motion control via the host system. (RMC100 motion controllers also
have an RS232 serial port for use with Delta’s RMCWin setup, tuning and
diagnostics package.) Your choice of a Comm Module will depend on the required
performance and compatibility match with your communication architecture.
Comm
Module
Protocols and Modes
Performance
-ENET
EtherNet/IP, CSP,
Modbus/TCP, CAMP, ISO-
on-TPC, FINS, HEI
10Mb, non-deterministic,
High data transfer, update
times vary
-PROFI
PROFIBUS DP Message
Mode or Compact Modes
9.6kb to 12Mb, deterministic,
high data transfer with
Message mode
-MB+
Modbus Plus with or
without Global Data
1Mb, deterministic, flexibility
allows high data transfer
-SERIAL
A-B DF1, Modbus/RTU,
Mitsubishi No Protocol
Mode, consult Delta for
others
RS232/RS422/RS485, 9.6kb
to 115,200kb data transfer.
Update times vary
-DI/O
Command Mode, Input to
Event, Parallel Event,
Parallel Position
Low data transfer. Events
can be triggered quickly
A short description of each communication module follows. The RMC part number
designation of each module is in parentheses.
Ethernet (-ENET)
The RMC100 offers a communication module for EtherNet/IP. This protocol is an
open protocol that has steadily been gaining popularity in the industrial world.
EtherNet/IP is innovative in that it combines the traditional messaging services with
higher-performance and more deterministic I/O services. The RMC ENET supports
both EtherNet/IP messaging and I/O. The Ethermet module can be used to
communicate with RMCWin.
Index/ENET/RMC Ethernet
Module Overview