beautypg.com

D-Link DI-206 User Manual

Page 72

background image

DI-206 ISDN Remote Router

60

Configuration and

Management

the gateway IP setting accordingly). And also make sure that the
Remote IP Address in the Remote Networks Profile is set to
0.0.0.0. Note that only one ISDN circuit should be connected to the
Internet, and only one ISDN circuit (the same one) should be the
default gateway.

Incoming

Name – The maximum length is 64 characters. This username

is for password challenges (authentication). The user dialing in
must supply this username in order to be allowed access to the
router.

Password – This is the password associated with the above

Name field.

Rem CLID – Remote Caller ID. This is the telephone number

of the Remote User and is used for security. When a phone
number is entered in this field, the router will make sure that the
incoming call is coming from the same phone number as the one
defined here. In other words, the remote user can only be
calling from the telephone number defined here, otherwise the
call will not be accepted. This function is disabled if the field is
left blank.

Call Back – This field determines whether the router calls back

after receiving a call from this Remote Network Profile. If this
option is enabled, the router will disconnect the initial call and
call back to the phone number that you provide. Note that this
field will be valid only if the Direction setting above is Both.

Outgoing

Name – The maximum length is 64 characters. Spaces and

punctuation are not usually accepted. This username is for