Administering the BioPointe
39
4.4.8 Deleting All Records
The following steps describe how all user records in the BioPointe can be deleted. To prevent accidental
deletion, two instances of master verifications are put in place.
Steps
LED and Buzzer Status
Press , , .
The LEDs will light up as shown in 1. The sensor
will also light up, waiting for a master fingerprint
to be verified.
Place the master finger on the sensor to
verify.
a) If the finger is successfully verified as a
master, the 1
st
LED will blink green briefly as
shown in 2(a). The 2
nd
LED will blink fast in
amber next. Proceed to step 3.
b) If the finger is not successfully verified as a
master, the 1
st
LED will blink red briefly.
Operation will cease and return to normal mode.
Press 3 times to proceed with the
operation.
Or,
Press once to abort.
When the # key is pressed 3 times, The 2
nd
LED
will blink fast in red as shown in 3. The sensor
will also light up to ask for the master fingerprint
verification again. Proceed to step 4.
If the * key is pressed, operation will cease and
return to normal mode.
Place the master finger on the sensor to verify.
a) If the finger is successfully verified as a
master, the 1
st
LED will blink green briefly as
shown in 4(a). The 3
rd
LED will blink slowly in
red next, indicating that the operation is in
progress. At the end of the operation, the 1
st
LED
will blink green briefly to indicate that the delete
all operation has been completed successfully.
b) If the finger is not successfully verified as a
master, the 1
st
LED will blink red briefly as
shown in 4(b). Operation ceases and will return
to normal mode.
1
1
AMBER
RED
2
2a
GREEN
→AMBER
AMBER
2b
RED
→AMBER
Master verification fails
3
3
AMBER
RED
4
4a
GREEN
→AMBER
4b
RED
→AMBER
Master verification fails,
delete-all not continued
AMBER
RED
GREEN
→AMBER