Stop leavening specifications
CT1SA0040101
Vers. 1.11

36/36

DL10 on, DL11 blinking during rising phase if the temperature setpoint was not reached.
DL10, DL11 on during a rising phase if the temperature setpoint was reached.

Slowing down
DL11, DL12, DL13 on during slowing down phase configuration.
DL12 on and DL13 off during slowing down phase if the temperature setpoint is equal to or higher than the
temperature setpoint of the rising phase.
DL12 off and DL13 on if the temperature setpoint is lower than the preset temperature setpoint for the rising
phase.

NOTE: The LEDs which refer to concluded phases will remain on while the next phases are running.