Stop leavening specifications
CT1SA0040101
Vers. 1.11

27/36



Qualsiasi ciclo in corso viene bloccato e tutte le uscite disattivate. Il buzzer si può tacitare premendo qualsiasi tasto.

Alla scomparsa dell’errore premere il tasto ON-STANDBY per riarmare la scheda.



Humidity probe
A probe breakdown causes a humidity probe breakdown alarm the buzzer will sound and the following alarm word will

be blinking on display:



The ongoing cycle will be interrupted and all outputs will be switched off. Press any key to silence the buzzer. The cycle

will resume as soon as the error disappears.


This signal is valid only if the humidity probe has been enabled by means of parameter P32.


Door micro switch
The door micro switch input is set through parameter P7:
P7 = 0: closed door = closed contact
P7 = 1: closed door = open contact

Each time the door is opened, the words ‘open door’ will start blinking:


When the door is opened during a quick cooling cycle, the fan, the resistances and the humidifier will stop; the

compressor and the steam generator will go off if parameter P72 has value 1 (otherwise they will remain on).

The buzzer will sound; press any key to silence it. The signal will automatically disappear as soon as the door is closed.
If parameter P71 has value 1, every time you open the door the light will be switched on.