beautypg.com

Connection diagram, Power basic connections, Power supply – EVCO CT1SA0040101 User Manual

Page 3: Outputs, Digital inputs, Analogue inputs

background image


Stop leavening specifications
CT1SA0040101
Vers. 1.11

3/36

1. CONNECTION DIAGRAM

1.1. Power Basic Connections

PO

W

ER

S

U

PPL

Y

PR B 1

PR B 2

IN 1

IN2

LO

A

D

6

LO

A

D

2

LO

A

D

1

LO

A

D

3

LO

A

D

7

LO

A

D

5

LO

A

D

4

K1

K2

K3

K4

K5

K6

K7

LINE

Imax = 6A

LINE

+

PR B 1

NO

NC

C

O

M

PR B 3

Power supply

NAME

DESCRIPTION

TYPE

POWER SUPPLY

POWER SUPPLY

12VAC +/- 15% 50/60HZ

Outputs

NAME

DESCRIPTION

TYPE

K1 (LOAD1)

COMPRESSOR

30A AC1 SPST

K2 (LOAD2)

DEFROST

8A AC1 SPDT

K3 (LOAD3)

SOLENOID VALVE/LIGHT/DEHUMIDIF

5A AC1 SPST

K4 (LOAD4)

STEAM GENERATING ENABLED

5A AC1 SPST

K5 (LOAD5)

EVAPORATOR FANS

5A AC1 SPST

K6 (LOAD6)

INJECTION SOLENOID VALVE

5A AC1 SPST

K7 (LOAD7)

RESISTANCES

8A AC1 SPDT

Digital Inputs

NAME

DESCRIPTION

TYPE

IN1

SAFETY THERMOSTAT INPUT

Free voltage

contact

IN2

DOOR MICRO SWITCH INPUT

Free voltage

contact

Analogue Inputs

NAME

DESCRIPTION

TYPE

RANGE

PRB1

CELL PROBE

NTC

-40°C – 100°C

PRB2

EVAPORATOR PROBE

NTC

-40°C – 100°C

PRB3

HUMIDITY PROBE

4-20mA (200Ohm)

0% - 100%