beautypg.com

Pre-cooling cycle, Menu 03 cool – EVCO CT1SA0040101 User Manual

Page 11

background image


Stop leavening specifications
CT1SA0040101
Vers. 1.11

11/36

11. PRE-COOLING CYCLE

You can run a pre-cooling cycle before executing any manual or automatic cycle.

While the machine is in standby mode, press the MENU key and select the COOL menu using the INCREASE and

DECREASE keys:



Press ENTER to access the temperature SetPoint change mode, as follows:






Press ENTER to access the change mode. The value in question will start blinking. Use the INCREASE and

DECREASE keys to change the value:






Press ENTER to confirm the setup value; the number will stop blinking. Press the START/STOP key to start the cycle.
With fans managing with output relay (parameter P45 = 0), during a pre cooling, the fans are activated parallel to

compressor.

With the fans proportional managing (parameter P45 = 1), during a pre cooling, the fans have the speed set up by the

parameter P58 when the compressor is on, otherwise the fans are off.


display will show:






The first line shows that a cooling cycle is running and that it is 06:18.
The second line shows that the temperature in the cell is -6°C.

Press MENU to return to SetPoint change.

Menu 03

Cool

SetTemperature

-12°C

SetTemperature

-11°C

SetTemperature

-12°C

Cool 06:18
T= -6°C