Stop leavening specifications
CT1SA0040101
Vers. 1.11

35/36

27.4. Visualization


DISPLAY DY1
Displays the temperature in the cell.
This is on during the cooling phase of a manual cycle, in the locking phase of the rising and during the preservation

phase of an automatic cycle.


DISPLAY DY2
Displays the relative humidity in the cell.
It will remain on during all phases which require humidity control.

DISPLAY DY3
Displays the temperature in the cell.
This is on during the heating and air conditioning phase of a manual cycle and in the awakening, rising and slowing

down phases of an automatic cycle.



DISPLAY DY4 UNIT
Displays date and time.
Displays date, month and real time with the card in standby or manual cycle.
Displays date, month and end of cycle time if the ongoing cycle is automatic.


LED SERIES

MANUAL CYCLE

Cooling
DL1, DL2, DL3, DL4, DL5, DL6 and DL7 on during cooling phase configuration.
DL1, DL2 on, DL3 blinking during cooling phase if the temperature setpoint was not reached.
DL1, DL2, DL3, DL4, DL5, DL6, DL7 on during a cooling phase if the temperature setpoint was reached.

Heating
DL7, DL8, DL9, DL10, DL11 on during heating phase configuration.
DL7, DL8 on, DL9 blinking during heating phase if the temperature setpoint was not reached.
DL7, DL8, DL9, DL10, DL11 on during a heating phase if the temperature setpoint was reached

Air conditioning
DL11, DL12, DL13 on during air conditioning phase configuration.
DL11 on, DL12 and DL13 blinking during air conditioning phase if the temperature setpoint was not reached.
DL11, DL12, DL13 on during an air conditioning phase if the temperature setpoint was reached.

AUTOMATIC CYCLE

Blocking
DL1, DL2, DL3 on during blocking phase configuration.
DL1, DL2 on, DL3 blinking during blocking phase if the temperature setpoint was not reached.
DL1, DL2, DL3 on during a blocking phase if the temperature setpoint was reached.

Preservation
DL3, DL4, DL5, DL6, DL7 on during preservation phase configuration.
DL4, DL5 on, DL6, DL7 blinking during preservation phase if the temperature setpoint was not reached.
DL4, DL5, DL6, DL7 on during a preservation phase if the temperature setpoint was reached.

Awakening
DL7, DL8, DL9 on during awakening phase configuration.
DL8 on, DL9 blinking during awakening phase if the temperature setpoint was not reached.
DL8, DL9 on on during an wakening phase if the temperature setpoint was reached.


Rising
DL9, DL10, DL11 on during rising phase configuration.