Stop leavening specifications
CT1SA0040101
Vers. 1.11

26/36

alternatively, when the evaporator probe is higher than parameter P60.


All defrost cycles will be interrupted when passing from the preservation phase to the awakening phase of an automatic

cycle.

At the end of the defrost cycle, you must wait for the end of the dripping time (parameter P63) before switching the

compressor on, and for the end of the fan stop time (parameter P63+P64) before switching the fans on.

Regarding compressor activation, safety time (parameters P26, P27 and P28) is still the priority.
Opening the door will not stop the compressor, but will cause the fans to go off, regardless of P64.

25. SIGNALS AND ALARMS

Both visual and acoustic signals will be given in case of malfunction. Below is the complete list of alarms/signals.

Cell probe
In case of a probe breakdown, a cell probe alarm will be given: the buzzer will sound and the display will show an error.



The ongoing cycle will be interrupted and all outputs will be switched off. Press any key to silence the buzzer. The cycle

will resume as soon as the error disappears.



Safety thermostat
The thermostat input is set by parameter P8:
P8= 0: thermostat alarm on = open contact
P8= 1: thermostat alarm on = closed contact

As soon as the card detects an alarm: the buzzer will sound and the following alarm will be shown on the display:




The ongoing cycle will be interrupted and all outputs will be switched off. Press any key to silence the buzzer. As soon

as the error disappears, press the ON-STANDBY key to reset the card.



Evaporator probe
A probe breakdown will cause an Evaporator Probe breakdown Alarm: the buzzer will sound and the following alarm

will start blinking on the display:



The ongoing cycle will be interrupted and all outputs will be switched off. Press any key to silence the buzzer. The cycle

will resume as soon as the error disappears.







High Temperature in the Evaporator
When P75=1, the high temperature alarm of the evaporator is enabled; if the evaporator probe reaches the value of

P74, the evaporator high temperature alarm will go off. The buzzer will sound and the display will show:

ALL CellSensor

ALL EvapSensor

ALL Thermostat