Stop leavening specifications
CT1SA0040101
Vers. 1.11
30/36
P36
Enables the humidification cycle during the stop phases of rising and
preservation phases
0 = disabled
1 = enabled
0 1 0
---
P37
Hysteresis for humidification
1
100
5
%
P38
Humidification dead zone
0
100
2
%
P39
Proportional Adjustment Band for Humidification
0
20
10
%
P40
Cycle time for Humidification Proportional Adjustment
1
255
30
seconds/minutes
P41
Time base for Cycle Time in proportional regulation humidifying
0 = seconds
1 = minutes
0 1 0
---
P42 Dehumidification
hysteresis
1
100
5
%
P43
Dehumidification dead zone
0
100
13
%
P44
Duration of Dehumidification attempt with solenoid valve
1
255
1
seconds
Fans
P45
Evaporator Fan Proportional Adjustment Enabling
0 = ON/OFF adjustment
1 = proportional adjustment
0 1 0
--
P46
Evaporator fan operation for rising stop
0 = simultaneous operation
1 = continuous operation
0 1 0
--
P47
Evaporator fan operation for preservation
0 = simultaneous operation
1 = continuous operation
0 1 0
--
P48
Evaporator fan operation for awakening
0 = simultaneous operation
1 = continuous operation
0 1 1
--
P49
Evaporator fan operation for rising
0 = simultaneous operation
1 = continuous operation
0 1 1
--
P50
Evaporator fan operation for slowing down
0 = simultaneous operation
1 = continuous operation
0 1 1
--
P51
Evaporator fan operation for refrigeration
0 = simultaneous operation
1 = continuous operation
0 1 0
--
P52
Evaporator fan operation for heating
0 = simultaneous operation
1 = continuous operation
0 1 1
--
P53
Evaporator fan operation for climatization
0 = simultaneous operation
1 = continuous operation
0 1 1
--
P54
Evaporator fan off delay in simultaneous operation
0
255
1
minutes
P55
Evaporator fan working time in simultaneous operation
0
255
3
minutes
P56
Evaporator fan pause time in simultaneous operation
0
255
1
minutes
P57
Evaporator fan minimum speed
0
100
0
%
P58
Evaporator fan speed during pre cooling cycle
P57
100
100
%
P59
Evaporator fan minimum speed during dehumidification
P57
100
20
%
Defrost
P60
Evaporator temperature for defrost end
-40
99
2
°C
P61
Time between two consecutive defrost cycles
0 = no defrost will be repeated
0 10 6
ore
P62
Defrost cycle max. duration
1
120
30
minutes
P63 Dripping
time
0 30 2
minutes
P64
Fan status during the defrost cycle
0
1
0
--
P65
Fan stop duration after dripping
0
15
3
minutes
Cooling
P66
Minimum setpoint for cooling
-30
P67
-3
°C
P67
Maximum setpoint for cooling
P66
30
10
°C
P68 Cooling
preset
P66
P67
2
°C
Program setting and change
P69
Enable program setting
0
1
1
--
P70
Enable program change
0
1
1
--