+EB - Break Handling in Error Control Operation

This extended-format compound parameter controls the break handling in V.42
operation. It accepts three numeric subparameters:

Syntax

+EB=[[,[,]]]

Defined Values

Decimal number 0 specifying that break is to be ignored, i.e.,
not signaled to remote DCE.

Decimal number 0 specifying that any transmitted V.42 L-
SIGNAL will not indicate break signal length

Decimal number 0 specifying that break is not delivered to the
DTE.

Reporting Current or Selected Values

Command: +EB?

Response:

+EB: ,,

Example:

+EB: 0,0,0

For default settings.

Reporting Supported Range of Parameter Values

Command: +EB=?

Response:

+EB: ( range),( range),
(default_length> range)

Example:

+EB: (0),(0),(0)

+ESR - Selective Repeat

This extended-format numeric parameter controls the use of the selective repeat (SREJ)
option in V.42.

Syntax

+ESR=[]

Decimal number 0 specifying that SREJ is not used.

Reporting Current or Selected Values:

Command: +ESR?

Response:

+ESR:

Example:

+ESR: 0