beautypg.com

Comtrol AT Command Set Rev A User Manual

Page 208

background image

AT Commands Reference Manual

Conexant

100722B

6-10

+VIT - Voice Inactivity Timer (DTE/Modem)

This command sets the modem’s initial value for the DTE/modem inactivity timer.

Syntax

+VIT=

Defined Values

Decimal number corresponding to the time in units of 1.0
second. A value of 0 disables the timer.

Reporting Current or Selected Values

Command: +VIT?

Response:

Example:

0

For the default setting.

Reporting Supported Range of Parameter Values

Command: +VIT=?

Response:

range

Example:

0-255

Result Codes

OK

= 0-255.

ERROR

Otherwise, or if not in Voice Mode.