Comtrol AT Command Set Rev A User Manual
Page 131

AT Commands Reference Manual
100722B
Conexant
3-105
S25 - Delay To DTR Off
S25 sets the length of time that the modem will ignore DTR for taking the action
specified by &Dn. Its units are seconds for synchronous modes and one hundredths of a
second for other modes.
Range:
0-255 (1 second for synchronous modes 1; 0.01 second otherwise)
Default: 5
S26 - RTS to CTS Delay
S26 sets the time delay, in hundredths of a second, before the modem turns CTS ON
after detecting an OFF-to-ON transition on RTS when &R0 is commanded. Pertains to
synchronous operation only.
Range:
0-255 hundredths of a second
Default: 1
S27 - Bit Mapped Options Status
S27 indicates the status of command options.
Default: 73 (49h) (01001001b)
Bits 0,1,3 Synchronous/asynchronous selection (&Mn/&Qn)
3 1
0
0 0
0
=
&M0 or &Q0
0 0
1
=
&M1 or &Q1
0 1
0
=
&M2 or &Q2
0 1
1
=
&M3 or &Q3
1 0
0
=
Reserved
1 0
1
=
&Q5 (Default.)
1 1
0
=
&Q6
Bit 2
Leased line control (&Ln)
0 =
Dial up line (&L0) (Default.)
Bits 4 - 5 Internal clock select (&Xn)
0 =
Internal clock (&X0) (Default.)
1 =
External clock (&X1)
2 =
Slave clock (&X2)
Bit 6
CCITT/Bell mode select (Bn)
0 =
CCITT mode (B0)
1 =
Bell mode (B1) (Default.)
Bit 7 - Reserved