Comtrol AT Command Set Rev A User Manual
Page 49

AT Commands Reference Manual
100722B
Conexant
3-23
&C - RLSD (DCD) Option
The modem controls the RLSD output in accordance with the parameter supplied. The
parameter value, if valid, is written to S21 bit 5.
Syntax
&C
Defined Values
Decimal number corresponding to the selected option.
0
RLSD remains ON at all times.
1
RLSD follows the state of the carrier. (Default.)
Result Codes
OK
0 or 1.
ERROR
Otherwise.
&D - DTR Option
This command interprets the ON to OFF transition of the DTR signal from the DTE in
accordance with the parameter supplied. The parameter value, if valid, is written to S21
bits 3 and 4. Also, see S25.
Syntax
&D
Defined Values
Decimal number corresponding to the selected option.
0
DTR drop is interpreted according to the current
&Qn setting as follows:
&Q0, &Q5, &Q6: DTR is ignored (assumed
ON). Allows operation with DTEs which do not
provide DTR.
&Q1: DTR drop causes the modem to hang up.
Auto-answer is not affected.
&Q2, &Q3: DTR drop causes the modem to
hang up. Auto-answer is inhibited.
1
DTR drop is interpreted according to the current
&Qn setting as follows:
&Q0, &Q1, &Q5, &Q6: DTR drop is interpreted
by the modem as if the asynchronous escape
sequence had been entered. The modem returns
to asynchronous command state without
disconnecting.